{"id":2015,"date":"2020-04-14T20:56:14","date_gmt":"2020-04-14T20:56:14","guid":{"rendered":"http:\/\/digitron-ist.co.rs\/new\/?p=2015"},"modified":"2020-04-14T21:16:37","modified_gmt":"2020-04-14T21:16:37","slug":"sinclair-st-500mcs","status":"publish","type":"post","link":"https:\/\/digitron-ist.co.rs\/new\/sinclair-st-500mcs\/","title":{"rendered":"SINCLAIR ST-500MCS"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.0.3&#8243; custom_margin=&#8221;-84px|||||&#8221; custom_padding=&#8221;3px||0px|||&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.0.3&#8243; width=&#8221;100%&#8221; min_height=&#8221;616px&#8221; custom_margin=&#8221;|auto||-3px||&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.0.3&#8243;][et_pb_image src=&#8221;http:\/\/digitron-ist.co.rs\/new\/wp-content\/uploads\/2020\/04\/SINCLAIR-ST-500MC-500MCS.jpg&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.0.3&#8243;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.0.3&#8243;][et_pb_text _builder_version=&#8221;4.0.3&#8243; hover_enabled=&#8221;0&#8243;]<\/p>\n<ul>\n<li>Kombinovani akumulacioni rezervoar kapaciteta 500 litara<\/li>\n<li>Slu\u017ei za akumulaciju i distribuciju termalne energije vode za grejanje<\/li>\n<li>Kompaktna izvedba, stoje\u0107i<\/li>\n<li>Opremljen toplotnim izmenjiva\u010dem od ner\u0111aju\u0107eg \u010delika za grejanje potro\u0161nje tople vode<\/li>\n<li>Toplotni izmenjiva\u010d od ner\u0111aju\u0107eg \u010delika za priklju\u010divanje na solarni sistem grejanja<\/li>\n<li>Mogu\u0107nost direktne ugradnje elektri\u010dnih greja\u010da snage do 6kW<\/li>\n<li>Spolja\u0161nja povr\u0161inska obrada: sivi skaj<\/li>\n<li>PU penasta izolacija debljine 50 mm<\/li>\n<\/ul>\n<table style=\"width: 444px; float: left;\" cellspacing=\"2\" cellpadding=\"2\" border=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Kapacitet rezervoara (l)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>500<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Kapacitet izmenjiva\u010da (l)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>17,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Kapacitet solarnog izmenjiva\u010da (l)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>5,8<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Grejna povr\u0161ina izmenjiva\u010da (m2)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>4,05<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Povr\u0161ina izmenjiva\u010da solarnog kruga\u00a0(m2)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>1,35<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Maks. pritisak rezervoar\/izmenjiva\u010d \/ solarni izmenjiva\u010d (MPa)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>0,6 \/ 1,0 \/ 1,0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Testiraju\u0107i pritisak rezervoar\/izmenjiva\u010d \/ solarni izmenjiva\u010d (<span>MPa)<\/span><\/td>\n<td style=\"height: 24px; width: 153px;\"><span>0,85 \/ 1,45 \/\u00a01,45<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Maks. temperatura rezervoar\/izmenjiva\u010d \/ solarni izmenjiva\u010d (<span>\u00b0C)<\/span><\/td>\n<td style=\"height: 24px; width: 153px;\"><span>110 \/ 110 \/ 110<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Te\u010dnost rezervoar \/ izmenjiva\u010d \/\u00a0solarni izmenjiva\u010d<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>grejanje vode \/ topla voda \/\u00a0grejanje vode<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 274px;\">Pre\u010dnik cevi ulaz \/ izlaz (mm)<\/td>\n<td style=\"height: 24px; width: 153px;\"><span>DN23\u00a0 \/ DN23<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.0.3&#8243; custom_margin=&#8221;-84px|||||&#8221; custom_padding=&#8221;3px||0px|||&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.0.3&#8243; width=&#8221;100%&#8221; min_height=&#8221;616px&#8221; custom_margin=&#8221;|auto||-3px||&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.0.3&#8243;][et_pb_image src=&#8221;http:\/\/digitron-ist.co.rs\/new\/wp-content\/uploads\/2020\/04\/SINCLAIR-ST-500MC-500MCS.jpg&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.0.3&#8243;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.0.3&#8243;][et_pb_text _builder_version=&#8221;4.0.3&#8243; hover_enabled=&#8221;0&#8243;] Kombinovani akumulacioni rezervoar kapaciteta 500 litara Slu\u017ei za akumulaciju i distribuciju termalne energije vode za grejanje Kompaktna izvedba, stoje\u0107i Opremljen toplotnim izmenjiva\u010dem od ner\u0111aju\u0107eg \u010delika za grejanje potro\u0161nje tople vode Toplotni izmenjiva\u010d od ner\u0111aju\u0107eg \u010delika za [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2003,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[67,7,24],"tags":[],"class_list":["post-2015","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-samostalni-rezervoari-za-vodu","category-sinclair","category-toplotne-pumpe"],"_links":{"self":[{"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/posts\/2015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/comments?post=2015"}],"version-history":[{"count":3,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/posts\/2015\/revisions"}],"predecessor-version":[{"id":2020,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/posts\/2015\/revisions\/2020"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/media\/2003"}],"wp:attachment":[{"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/media?parent=2015"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/categories?post=2015"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/digitron-ist.co.rs\/new\/wp-json\/wp\/v2\/tags?post=2015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}